Automatically shuts off power when excessive voltage, low (<102V) and high (>132V), or open ground/neutral conditions are present. Auto Reset on power restoration. LCD display shows voltage and amp draw on all legs. Shows faults (when occurred) for open neutral, open ground, reverse polarity, miswired pedestal, elevated ground voltage. 128 second reset delay. Convenient plug handles. Weather resistant.